Bellows replacement, seal kits, complete overhaul: we repair aseptic valves of all common brands in our Munich workshop. These include GEA / Tuchenhagen, Pentair Südmo, Alfa Laval, SPX APV, GEMÜ, Bardiani, KIESELMANN. The inspection is free, repairs only start after your approval.

How your valve comes back tested.
A valve that no longer separates the process safely does not belong in the bin. Most of the time it belongs in the workshop.
The most common case: the bellows is fatigued, housing and actuator are intact. We replace single and double bellows including the seal kit, with FDA-compliant materials and documentation.
Announce your shipmentReworking the seat, checking the stem, all product-contact seals renewed: after the overhaul the valve is tested and returned with documentation in our QM system to DIN EN ISO 9001.
Request an inspectionNo longer repairable? Then we say so honestly and supply the equivalent replacement valve or the matching bellows kit from our range.
Request a quoteFounded in Munich in 1980, experience across generations of plants.
Every repaired part leaves the workshop tested and documented.
On working days a technician from the workshop usually gets back to you within 24 hours with a first assessment.
Documented processes from goods receipt to final inspection. Scope of certification: mechanical seals.
Bellows replacement, overhaul or replacement valve?
As a guide from the workshop, binding after the free inspection:
| Finding | Typical cause | Recommendation |
|---|---|---|
| Bellows cracked or hardened | Fatigue from switching cycles, SIP temperature cycles | Bellows replacement with seal kit: the standard case and the most economical solution |
| Leakage at the seat | Wear of the seat seal, deposits | Reworking the seat, renewing seals: part of the overhaul |
| Leakage chamber alarm on double bellows | Inner bellows damaged | Send in immediately: replace both bellows, check the monitoring |
| Stem stiff | Actuator or guide worn | Overhaul with actuator check |
| Housing corroded or damaged | Medium, mechanical damage | Replacement valve: housing damage is rarely economical to repair |
Hygiene note: Valves from food and beverage processes can be sent in as removed. Cleaning is part of the free inspection. A completed CIP run speeds up the inspection but is not required. For hazardous, toxic or corrosive media, send the valve in free of residues and enclose a short, informal declaration of decontamination. Shipping address & process (German) ›
In case of downtime
On working days a direct line to a technician. No hotline, no queue.
+49 89 45 20 940‑0 Mon–Thu 7:30–16:30 · Fri 7:30–14:00 CET · Langwieder Hauptstraße 2–4 · 81249 Munich, GermanyWhat we are asked about aseptic valve repair.
Do you also repair double bellows valves?
Yes, including replacement of both bellows and a check of the leakage chamber monitoring. With double bellows in particular, repair almost always pays off. How to recognise a bellows that is due is explained in our guide (in German) When the bellows needs replacing (German).
Which brands do you repair?
All the common ones: GEA / Tuchenhagen, Pentair Südmo, Alfa Laval, SPX APV, GEMÜ, Bardiani, KIESELMANN and others. Being brand-independent is our core.
How quickly is the valve back?
We state the realistic turnaround time with the fixed quote after the inspection. Mark downtime in your inquiry; it is prioritised.
Are the spare parts food-compliant?
We supply product-contact materials compliant with FDA or Regulation (EC) No. 1935/2004, on request with a declaration of conformity for your audit.
Contact
Announce your shipment.
The workshop is expecting your valve, the inspection is free, and repairs only start after your approval.